Journal Article

Monitoring of exposure to acrylonitrile by determination of <i>N</i>-(2-cyanoethyl)valine at the N-terminal position of haemoglobin

R. Tavares, H. Borba, M. Monteiro, MJ. Proença, N. Lynce, J. Rueff, E. Bailey, G.M.A. Sweetman, R.M. Lawrence and P.B. Farmer

in Carcinogenesis

Volume 17, issue 12, pages 2655-2660
Published in print December 1996 | ISSN: 0143-3334
Published online December 1996 | e-ISSN: 1460-2180 | DOI: http://dx.doi.org/10.1093/carcin/17.12.2655
Monitoring of exposure to acrylonitrile by determination of
                        N-(2-cyanoethyl)valine at the N-terminal position of
                    haemoglobin

More Like This

Show all results sharing this subject:

  • Clinical Cytogenetics and Molecular Genetics

GO

Show Summary Details

Preview

A selected ion monitoring gas chromatography-mass spectrometry (GC-MS) procedure was developed to determine the interaction product formed by acrylonitrile (ACN) with the N-terminal amino group in haemoglobin. The product, N-(2-cyanoethyl)valine (CEV), was analysed following its release from the protein by a modified Edman degradation procedure. Quantitation was achieved using N-(2-cyanoe-thyl)-[2H8]Val-Leu-Ser as internal standard. The limit of detection of the assay was 1 pmol CEV/g globin. A close to linear dose-response relationship was found for adduct formation in rats treated with ACN by gavage. On the basis of a linear extrapolation, a dose of 1 mg/kg body wt yielded 248 pmol CEV/g globin. Two groups of workers who were exposed to ACN contained 1984 ± SD 2066 (n = 9) and 2276 ± SD 1338 (n = 7) pmol CEV/g globin respectively. These values were highly significantly greater (P < 0.01 following a one-way analysis of variance with a logarithmic transformation of the data) than those in a group of control workers in the same factory (31.1 ± SD 18.5 pmol CEV/g globin, n = 11). The concentrations of N-terminal CEV in globin samples from 13 smoking and 10 non-smoking mothers and from their newborns were determined. Adduct levels in the smokers averaged 217 ± 85.1 pmol CEV/g globin, significantly higher than the levels in non-smokers, which were undetectable. Individual values in the mothers were very highly correlated with the levels in their babies (which averaged 99.5 ± 53.8 praol CEV/g globin), which demonstrates that transplacental transfer of ACN occurs. Significant correlations were also found between the number of cigarettes smoked per day by the mother and the CEV levels in both the mothers‘ and newborns’ globin. There was, however, no correlation between the CEV levels and those of the ethylene oxide adduct N-(2-hydroxyethyl)valine in samples from either the mothers or babies.

Journal Article.  0 words. 

Subjects: Clinical Cytogenetics and Molecular Genetics

Full text: subscription required

How to subscribe Recommend to my Librarian

Users without a subscription are not able to see the full content. Please, subscribe or login to access all content.