Journal Article

Evaluation of an antimicrobial and fluoride-releasing self-etching primer on the shear bond strength of orthodontic brackets

H Korbmacher, L Huck, T Adam and B Kahl-Nieke

in The European Journal of Orthodontics

Published on behalf of European Orthodontics Society

Volume 28, issue 5, pages 457-461
Published in print October 2006 | ISSN: 0141-5387
Published online June 2006 | e-ISSN: 1460-2210 | DOI: http://dx.doi.org/10.1093/ejo/cjl013
Evaluation of an antimicrobial and fluoride-releasing self-etching primer on the shear bond strength of orthodontic brackets

More Like This

Show all results sharing this subject:

  • Restorative Dentistry and Orthodontics

GO

Show Summary Details

Preview

The enhanced risk of dental caries is one negative side-effect of fixed appliances. A new antimicrobial and fluoride-releasing self-etching bonding system (Clearfil Protect Bond™) has been introduced in restorative dentistry and clinical studies have already shown the potential for this primer to be used clinically with effective antiplaque properties. Therefore, this in vitro study was conducted in order to evaluate the new primer in comparison with a conventional bonding preparation.

One hundred and twenty extracted human teeth were randomly divided into three groups of 40 specimens each (20 incisors, 20 premolars). In group 1 a conventional bonding procedure was used (etching, Transbond XT), in group 2 the new primer was used according to the manufacturer's recommendations when bonding to intact enamel, while in group 3 the new primer was used without prior etching. Shear bond strength (SBS) was measured with a universal testing machine and the adhesive remaining after debonding was determined using an optical microscope at ×10 magnification. The adhesive remnant index was used in order to assess the mode of failure.

No enamel fractures were detected in any of the specimens. In all groups acceptable bond strengths were observed. The only statistically significant difference (P = 0.004) was found for the incisors in group 2, which showed the highest mean SBS (17.46 MPa).

Considering the acceptable bond strength and the mode of failure, use of the new primer without prior etching is recommended in patients with fixed appliances. Further in vivo studies will be carried out in order to evaluate clinical performance.

Journal Article.  2552 words.  Illustrated.

Subjects: Restorative Dentistry and Orthodontics

Full text: subscription required

How to subscribe Recommend to my Librarian

Users without a subscription are not able to see the full content. Please, subscribe or login to access all content.