Comparison of Cozart<sup>®</sup> Microplate ELISA and GC-MS Detection of Methadone and Metabolites in Human Hair

Gail Cooper, Lisa Wilson, Claire Reid, Dene Baldwin, Chris Hand and Vina Spiehler

in Journal of Analytical Toxicology

Volume 29, issue 7, pages 678-681
Published in print October 2005 | ISSN: 0146-4760
Published online October 2005 | e-ISSN: 1945-2403 | DOI: http://dx.doi.org/10.1093/jat/29.7.678
Comparison of Cozart® Microplate ELISA and GC-MS Detection of Methadone and Metabolites in Human Hair

More Like This

Show all results sharing these subjects:

  • Medical Toxicology
  • Toxicology (Non-medical)

GO

Show Summary Details

Preview

The purpose of this study was to determine the performance characteristics of the Cozart Methadone Microplate ELISA assay for the detection of methadone and methadone metabolites in hair specimens. One hundred and ten hair specimens were collected from volunteers (n = 46) with a history of drug use and from drug-related deaths (n = 64). The hair samples (approximately 20 mg) were extracted by sonication in methanol followed by overnight extraction in methanol at 60°C. The methanol extract was evaporated to dryness, reconstituted in ELISA negative calibrator, and then analyzed. For gas chromatography-mass spectrometry (GC-MS) analysis, deuterated internal standard mixture [methadone-d9 and 2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine (EDDP)-d3] and 0.1M HCl were added to approximately 20 mg of specimen or spiked blank hair and sonicated for 1 h. The pH was adjusted to neutral, and methadone and its primary metabolite, EDDP, were analyzed by GC-MS following solid-phase extraction using Bond Elute Certify columns and pH 7.4 phosphate buffer (0.1M). Forty hair specimens were confirmed positive for methadone by GC-MS. Concentrations ranged from 0.10 to 8.3 ng/mg for methadone and 0.1 to 1.2 ng/mg for EDDP. The true positives, true negatives, false positives, and false negatives for different cutoffs with the ELISA were determined by comparison of the ELISA response (normalized to weight of hair extracted) to the GC-MS results with a cutoff of 0.1 ng/mg for both methadone and EDDP as the reference method. The optimum cutoff for the Cozart Methadone Microplate ELISA was determined to he between 200 and 300 pg methadone equivalents/rag hair using a 20 mg hair sample. The Cozart Methadone Microplate EIA for methadone and metabolites in hair using a cut-off of 200 pg/mg hair with a 20 mg hair sample had a sensitivity of 95 ± 2% and a specificity of 100 ± 3.5% (vs GC-MS) and an accuracy of 98.2 ± 1.3%.

Journal Article.  0 words. 

Subjects: Medical Toxicology ; Toxicology (Non-medical)