Complete Automation of Solid-Phase Extraction with Subsequent Liquid Chromatography-Tandem Mass Spectrometry for the Quantification of Benzoylecgonine, <i>m</i>-Hydroxybenzoylecgonine, <i>p</i>-Hydroxybenzoylecgonine, and Norbenzoylecgonine in Urine—Application to a High-Throughput Urine Analysis Laboratory*

Paul P. Robandt, Louis J. Reda and Kevin L. Klette

in Journal of Analytical Toxicology

Volume 32, issue 8, pages 577-585
Published in print October 2008 | ISSN: 0146-4760
Published online October 2008 | e-ISSN: 1945-2403 | DOI: http://dx.doi.org/10.1093/jat/32.8.577
Complete Automation of Solid-Phase Extraction with Subsequent Liquid Chromatography-Tandem Mass Spectrometry for the Quantification of Benzoylecgonine, m-Hydroxybenzoylecgonine, p-Hydroxybenzoylecgonine, and Norbenzoylecgonine in Urine—Application to a High-Throughput Urine Analysis Laboratory*

More Like This

Show all results sharing these subjects:

  • Medical Toxicology
  • Toxicology (Non-medical)

GO

Show Summary Details

Preview

A fully automated system utilizing a liquid handler and an online solid-phase extraction (SPE) device coupled with liquid chromatography-tandem mass spectrometry (LC-MS-MS) was designed to process, detect, and quantify benzoylecgonine (BZE), meta-hydroxybenzoylecgonine (m-OH BZE), para-hydroxybenzoylecgonine (p-OH BZE), and norbenzoylecgonine (nor-BZE) metabolites in human urine. The method was linear for BZE, m-OH BZE, and p-OH BZE from 1.2 to 10,000 ng/mL with limits of detection (LOD) and quantification (LOQ) of 1.2 ng/mL. Nor-BZE was linear from 5 to 10,000 ng/mL with an LOD and LOQ of 1.2 and 5 ng/mL, respectively. The intrarun precision measured as the coefficient of variation of 10 replicates of a 100 ng/mL control was less than 2.6%, and the interrun precision for 5 replicates of the same control across 8 batches was less than 4.8% for all analytes. No assay interference was noted from controls containing cocaine, cocaethylene, and ecgonine methyl ester. Excellent data concordance (R2 > 0.994) was found for direct comparison of the automated SPE-LC-MS-MS procedure and an existing gas chromatography-MS procedure using 94 human urine samples previously determined to be positive for BZE. The automated specimen handling and SPE procedure, when compared to the traditional extraction schema, eliminates the human factors of specimen handling, processing, extraction, and derivatization, thereby reducing labor costs and rework resulting from batch handling issues, and may reduce the number of fume hoods required in the laboratory.

Journal Article.  0 words. 

Subjects: Medical Toxicology ; Toxicology (Non-medical)

Full text: subscription required

How to subscribe Recommend to my Librarian

Users without a subscription are not able to see the full content. Please, subscribe or login to access all content.