Journal Article

Improving hand hygiene compliance rates in the haemodialysis setting: more than just more hand rubs

Simone Scheithauer, Frank Eitner, Jennifer Mankartz, Helga Haefner, Katharina Nowicki, Jürgen Floege and Sebastian W. Lemmen

in Nephrology Dialysis Transplantation

Published on behalf of European Renal Association - European Dialysis and Transplant Assoc

Volume 27, issue 2, pages 766-770
Published in print February 2012 | ISSN: 0931-0509
Published online July 2011 | e-ISSN: 1460-2385 | DOI: http://dx.doi.org/10.1093/ndt/gfr365
Improving hand hygiene compliance rates in the haemodialysis setting: more than just more hand rubs

Show Summary Details

Preview

Background.

Haemodialysis patients are at high risk for developing healthcare-associated infections as well as acquiring multidrug-resistant microorganisms. Hand hygiene is considered to be the single most effective tool to prevent healthcare-associated infections. The number of indications and the extent of indication-specific compliance with hand rubs in the haemodialysis setting are currently unknown.

Methods.

We conducted a prospective, three-phase, observational intervention study on hand hygiene during haemodialysis treatments. Optimized hand hygiene standard operating procedures (SOPs) for dialysis connections (Intervention I) and disconnections (Intervention II) were compiled and implemented during two predefined intervention periods.

Results.

A total of 8897 indications for hand rubs were observed throughout this study. In the course of the study, we identified an increase in the number of hand rubs performed (6–9, mean number per dialysis procedure), parallelled by a decrease in the indications for hand rubs (21–15), resulting in a significant increase of overall hand rub compliance (30–62%). The greatest improvement was seen before aseptic tasks (21–52%), the indication with the greatest impact on preventing healthcare-associated infections. There was no difference between haemodialysis via central venous catheter access or arterio-venous (AV) fistulas.

Conclusions.

This study provides the first detailed data on the number of and indications for hand rubs during dialysis. An >100% increase in overall hand hygiene compliance could be achieved by a comparably moderate increase in hand rubs performed in combination with optimized hand hygiene SOPs.

Keywords: compliance; haemodialysis; hand hygiene; health- care-associated infection; infection control; surveillance

Journal Article.  2960 words.  Illustrated.

Subjects: Nephrology

Full text: subscription required

How to subscribe Recommend to my Librarian

Users without a subscription are not able to see the full content. Please, subscribe or login to access all content.