BACKGROUND
Recent neonatal resuscitation guidelines have suggested the potential benefit of introducing Electrocardiography (ECG) to monitor neonatal heart rate (HR) as standard of care for newborns receiving respiratory support in the delivery room due to advantages over auscultation.
OBJECTIVES
To assess effectiveness of HR detection using either ECG or auscultation.
DESIGN/METHODS
We reviewed recordings from our piglet neonatal resuscitations to compare an ECG with auscultation for assessing the detection of HR at cardiac arrest. Term newborn piglets (n=41) were anesthetized, intubated, instrumented, and exposed to 40-min normocapnic hypoxia followed by asphyxia, which was achieved by clamping the endotracheal tube until asystole. Asystole was confirmed by using Electrocardiography and auscultation.
RESULTS
The median (±IQR) duration of asphyxia was 318 (200–560)sec. In 41 piglets both auscultation and ECG HR were assessed. In 11 (27%) cases both auscultation and ECG correctly identified a bradycardic HR (mean (SD) 32(14)/min) at the beginning of chest compression. In 11 (27%) cases both auscultation and ECG correctly identified absent of any HR. However, in 19 (46%) cases auscultation did not detect a HR while ECG did detect a HR. Overall, the Positive Predictive Value was 37%, Negative Predictive Value was 100%, Sensitivity was 100%, and Specificity was 37% for the ECG to display accurate HR during asphyxia in newborn piglets.
CONCLUSION
Our data illustrates the need for caution in the routine use of ECG monitoring for all neonatal who might need advanced resuscitation in the deliver room.
Journal Article. 0 words.
Subjects: Neonatology ; Primary Care ; Child and Adolescent Psychiatry ; Clinical Child and Adolescent Psychology ; Developmental Psychology
Full text: subscription required
How to subscribe Recommend to my Librarian
Users without a subscription are not able to see the full content. Please, subscribe or login to access all content. subscribe or login to access all content.